Mastering Bomba Fire Certification in Malaysia: Your 2026 Complete Guide to Approval

Complete guide to obtaining a BOMBA fire certificate (FC) in Malaysia. Covers the Fire Services Act 1988, designated premises categories, application through the SPKA system, JBPM inspection requirements, fees, renewal process, and penalties for non-compliance.

Fire safety inspection for certification at a commercial building in Malaysia

Why Factory BOMBA Compliance Is Different from Standard Buildings

Factories face stricter BOMBA fire compliance requirements than standard commercial buildings. Higher occupancy loads, hazardous materials, heavy machinery generating heat, and large open-plan layouts create fire risks that do not exist in typical offices or retail spaces. JBPM (Jabatan Bomba dan Penyelamat Malaysia) applies more demanding standards to industrial premises accordingly.

Operating a factory without a valid Fire Certificate (FC) from BOMBA is an offence under Section 28 of the Fire Services Act 1988, carrying penalties up to RM100,000 or imprisonment up to 3 years. Beyond the legal requirement, your fire insurance and IAR policy can be voided if BOMBA compliance has lapsed at the time of a fire.

This guide covers BOMBA fire compliance specifically for factories and industrial buildings. For the general FC application and renewal process, refer to our BOMBA Fire Certificate application guide.

Fire Protection Systems Required for Factories

The fire protection systems required for your factory depend on building size, height, occupancy class, and the nature of materials stored or processed. JBPM classifies these into active systems (require activation) and passive systems (built-in structural features).

Active Fire Protection Systems

System Standard When Required Factory-Specific Considerations
Fire alarm and detection system MS 1745 / BS 5839 All factory buildings Detector type must suit environment (heat detectors for dusty areas, not smoke)
Portable fire extinguishers (APA) MS 1539 All factory buildings Type must match fire class; eFEIS registration required
Hose reel system MS 1123 Buildings exceeding specified floor area Hose reach must cover all corners of large production floors
Wet riser / dry riser UBBL 1984 Multi-storey factories exceeding 18m height Dry risers for unheated areas; wet risers need frost protection
Automatic sprinkler system MS 1910 Factories storing hazardous materials, buildings over specified size Sprinkler design density varies by hazard classification (OH, HH, EHH)
Emergency lighting and exit signs MS 1553 All factory buildings Battery backup must provide minimum 1.5 hours; test monthly
Fire hydrant system (external) UBBL 1984 Factories above specified size or hazard class BOMBA access road must reach hydrant points within 45m of building

Passive Fire Protection Systems

System Purpose Factory Requirements
Fire-rated walls and partitions Contain fire spread between compartments 1-4 hour rating depending on factory hazard class and compartment size
Fire doors Maintain compartmentation at openings Self-closing with 30 min to 2 hour rating; must not be propped open
Fire stops and penetration seals Seal gaps where services penetrate fire walls Often neglected in factories after cable/pipe additions; must be resealed
Protected escape routes Safe egress paths for occupants Travel distance limits: 30m (single direction), 45m (two directions) for factories
Smoke management / ventilation Control smoke movement during fire Natural vents or mechanical smoke extraction for large open-plan factories

The most common passive fire protection failure in factories is fire stops. When new cables, pipes, or ductwork are installed, the penetrations through fire walls must be resealed with fire-rated materials. This is almost always missed during factory renovations and expansions.

Fire Protection Requirements by Factory Type

Different factory types present different fire hazards. JBPM and insurers classify factories by hazard level, which determines the fire protection systems required and the insurance premium applied.

Factory Type Hazard Class Key Fire Risks Additional Systems Typically Required
Electronics / Semiconductor Ordinary Hazard (OH) Clean room chemicals, electrical equipment density Gas suppression for clean rooms, VESDA early detection
Food Processing Ordinary to High Hazard Cooking oils, flour dust, deep fryers Kitchen hood suppression, Class F extinguishers, dust extraction
Chemical / Petrochemical Extra High Hazard (EHH) Flammable liquids, reactive chemicals, vapour clouds Foam systems, gas detection, explosion-proof equipment, deluge systems
Plastics / Rubber High Hazard (HH) Combustible materials, extrusion heat, solvent-based adhesives High-density sprinklers, adequate separation distances
Textile / Garment Ordinary to High Hazard Combustible fabrics, dust accumulation, ironing/pressing Dust extraction, sprinklers in storage areas
Woodworking / Furniture High Hazard (HH) Wood dust, lacquers, adhesives, sawdust accumulation Dust collection with spark detection, sprinklers, extensive extinguisher coverage
Metal Fabrication / Welding Ordinary Hazard Hot work, cutting sparks, compressed gas cylinders Hot work permit system, gas cylinder storage compliance
Warehouse / Logistics Varies by stored goods High-rack storage, combustible packaging, limited access In-rack sprinklers for high-rack storage, smoke detection above racks

The hazard classification directly affects your insurance premium. A factory classified as Extra High Hazard will pay significantly more for fire and IAR insurance than one classified as Ordinary Hazard. Investing in proper fire protection can reduce both your hazard classification and your premium.

Preparing Your Factory for BOMBA Inspection

JBPM inspections for factory Fire Certificates are more detailed than inspections for standard commercial premises. Knowing exactly what inspectors check allows you to prepare systematically and avoid failures that delay your FC.

Inspection Area What JBPM Officers Check Common Factory Failures How to Prepare
Fire alarm panel Panel operation, zone configuration, fault indicators Disabled zones, unresolved faults, no log book Clear all faults, ensure all zones active, maintain log book
Sprinkler system Water pressure, valve positions, flow test Closed valves, low water pressure, painted sprinkler heads Run flow test, check all valves open, replace painted heads
Fire extinguishers Valid eFEIS stickers, correct type, accessible locations Expired eFEIS, wrong type for fire class, blocked access Complete eFEIS renewal before inspection
Escape routes Clear paths, proper signage, emergency lighting Routes blocked by pallets/stock, missing signs, dead batteries Clear all routes, test emergency lights, replace missing signs
Fire doors Self-closing function, seals intact, not propped open Doors wedged open for ventilation, missing seals, broken closers Remove wedges, replace seals and closers, train staff
BOMBA access road Width, clearance, turning radius for fire engines Containers/vehicles parked on access road, insufficient width Mark and enforce no-parking zones on BOMBA access routes
Fire safety management plan Written plan, assembly points, drill records No written plan, no drill records, outdated floor warden list Update plan, conduct drill before inspection, update warden list
Electrical installations No overloading, proper earthing, cable management Overloaded sockets, exposed wiring, unauthorised modifications Get electrical inspection done before BOMBA visit
Hazardous material storage Proper storage, labelling, SDS availability, spill containment Chemicals not in designated store, missing labels, no bunding Organise chemical store, label everything, install bunding

Schedule your internal pre-inspection audit at least 4 weeks before the BOMBA visit. This gives you time to fix any issues found. Rushing last-minute repairs is the most common cause of failed inspections.

Is your factory ready for the next BOMBA inspection? Fire compliance gaps can void your insurance coverage. Our team can help you understand how fire safety status affects your insurance programme.

Get a fire insurance review →

Fire Certificate Application Process for Factories

Factory FC applications go through the SPKA online portal (spka.bomba.gov.my). The process is the same as for other building types, but factories typically face more scrutiny during inspection due to higher hazard levels.

Step Action Timeline Factory-Specific Notes
1 Register on SPKA portal with company and building details 1-2 days Include all buildings on the factory compound
2 Submit Form I with building info and fire system documentation 1-3 days Attach fire system maintenance records, test certificates
3 Pay inspection fee (RM50-RM500 depending on size) 1 day Larger factories pay higher fees
4 JBPM inspection of premises Scheduled within 14-30 days Inspector may request access to all areas including restricted zones
5 Remediation (if issues found) Variable (days to weeks) Must fix all identified issues before re-inspection
6 FC issued via SPKA portal 1-5 days after pass Valid 12 months; set reminder for renewal 3 months before expiry

For a detailed walkthrough of the FC application and renewal process including all required documents, refer to our FC application and renewal guide.

FC Renewal Timeline for Factories

The Fire Certificate is valid for 12 months and must be renewed before expiry. Operating with an expired FC is an offence. Use this timeline to ensure your renewal is completed on time.

Time Before Expiry Action Responsibility
3 months Conduct internal fire safety audit of all systems Factory SHO or facility manager
2-3 months Fix all identified issues; complete APA eFEIS renewal Maintenance team + licensed contractors
2 months Submit Form III renewal via SPKA portal Factory admin / compliance officer
1-2 months Prepare for JBPM inspection visit SHO + facility manager
Before expiry Receive renewed FC via SPKA Automatically issued after passing inspection

Cost of Fire Protection for Factories

Fire protection is a significant capital investment for factories, but the cost of not having adequate protection is far greater. Beyond regulatory penalties, an uncontrolled factory fire can cause total loss of the premises and all contents.

System Estimated Cost Range (RM) Annual Maintenance (RM) Notes
Fire alarm system (small factory) 15,000 - 50,000 3,000 - 8,000 Addressable systems cost more but pinpoint fire location
Fire alarm system (large factory) 80,000 - 300,000 10,000 - 25,000 Multi-zone with integration to BMS
Sprinkler system 80,000 - 500,000+ 8,000 - 20,000 Cost per m² varies by hazard class; HH costs 2-3x OH
Hose reel system 20,000 - 80,000 3,000 - 6,000 Depends on number of hose reels and pipe runs
Fire extinguishers (20 units) 3,000 - 8,000 600 - 1,500 Plus eFEIS inspection fees
Emergency lighting 5,000 - 30,000 1,000 - 3,000 Battery replacement every 3-5 years
Fire doors (per door) 1,500 - 5,000 200 - 500 Higher-rated doors (2-hour) cost more
Gas suppression (server/clean room) 50,000 - 200,000 5,000 - 15,000 Novec 1230 or FM-200 systems

For a typical single-storey factory of 20,000 sq ft, budget RM150,000 to RM400,000 for a complete fire protection system installation. Annual maintenance costs run RM20,000 to RM50,000 depending on system complexity.

How Factory BOMBA Compliance Affects Your Insurance

Your fire insurance and IAR policy contain warranty conditions related to fire protection and BOMBA compliance. Breaching these warranties can result in claim denial. This is where BOMBA compliance directly impacts your financial protection.

BOMBA Compliance Status Insurance Impact Claims Outcome
Valid FC + all systems maintained Full coverage; potential premium discounts for sprinklered premises Claims processed normally; strong policyholder position
FC expired but systems maintained Warranty breach; coverage may be disputed Insurer may argue breach of policy condition; claim reduced or denied
Valid FC but systems not maintained Warranty breach; non-functional systems = no protection Insurer investigates whether non-functional system contributed to loss severity
No FC and no maintenance Material non-disclosure; coverage may be voided entirely Claim likely denied; insurer may void policy ab initio

Insurance policies for factories typically include specific fire protection warranties. A common warranty requires that "fire alarm systems and sprinklers shall be maintained in efficient working order at all times." If a fire occurs while your sprinkler system is shut down for maintenance without notifying the insurer, your claim can be denied.

Sprinkler Discount on Fire Insurance Premiums

Factories with JBPM-approved automatic sprinkler systems can receive premium discounts on fire and IAR insurance. The discount typically ranges from 20% to 40% depending on the system coverage and compliance record. This discount can more than offset the annual maintenance cost of the sprinkler system.

Not sure if your fire protection qualifies for insurance premium discounts? Our team can review your systems and insurance programme to identify savings opportunities.

Get a premium review →

Penalties for Factory Fire Non-Compliance

Offence Section Maximum Penalty
Operating without Fire Certificate Section 28, Fire Services Act 1988 RM100,000 fine and/or 3 years imprisonment
Failing to maintain fire safety systems Section 33 RM50,000 fine and/or 1 year imprisonment
Obstructing JBPM inspection Section 34 RM50,000 fine and/or 1 year imprisonment
Ignoring safety improvement notice Section 29 RM100,000 fine and/or 3 years imprisonment
Failure to provide APA (fire extinguishers) Section 29 RM5,000 fine and/or 3 years imprisonment

For comprehensive information on all BOMBA penalties and fines, refer to our dedicated guide.

Factory Fire Safety Management Plan

Every factory must have a written fire safety management plan. This is checked during BOMBA inspections and is also reviewed by insurers during HIRARC assessments. The plan should cover the following elements.

  • Fire risk assessment - Identifying fire hazards specific to your factory operations and materials
  • Emergency procedures - Clear evacuation procedures, assembly points, and accounting for all workers
  • Floor warden system - Designated wardens for each zone/floor with specific responsibilities
  • Fire drill schedule - Minimum two drills per year with documented results
  • System maintenance schedule - Planned maintenance for all fire protection systems with records
  • Hot work procedures - Permit system for welding, cutting, and other hot work activities
  • Chemical storage procedures - Specific rules for hazardous material storage and handling
  • Visitor and contractor fire safety briefing - Fire safety induction for all visitors and contractors on site

The fire safety management plan should be reviewed annually and updated whenever there are changes to factory layout, processes, materials, or occupancy. Keep copies accessible in the main office, security gatehouse, and on the factory floor.

Frequently Asked Questions

What fire protection systems does my factory need?

The specific systems depend on your factory's size, height, hazard classification, and the materials you process or store. At minimum, all factories need a fire alarm and detection system, portable fire extinguishers with valid eFEIS stickers, emergency lighting and exit signs, and clear escape routes. Larger or higher-hazard factories may also need sprinkler systems, hose reels, and external fire hydrants.

How often is a BOMBA inspection for factory Fire Certificate renewal?

The Fire Certificate is valid for 12 months and requires annual renewal. JBPM conducts an inspection as part of each renewal. Additionally, JBPM officers can conduct unannounced inspections at any time. Submit your Form III renewal application at least 2 months before your FC expires.

Can my factory operate while waiting for FC renewal?

You should maintain continuous FC coverage. If your renewal application is submitted before expiry and JBPM is processing it, you can generally continue operating. However, if your FC has already expired and no renewal is in process, you are technically operating without a valid FC which is an offence under Section 28.

What happens if my factory fails a BOMBA inspection?

JBPM will issue a list of non-compliance items that must be rectified. You will not receive the FC until all items are fixed and a re-inspection confirms compliance. If the issues are serious enough to pose an immediate danger, JBPM can issue a prohibition notice requiring you to stop operations until the issues are resolved.

Does having sprinklers reduce my fire insurance premium?

Yes. Factories with JBPM-approved automatic sprinkler systems typically receive premium discounts of 20% to 40% on fire and IAR insurance. The system must be properly maintained and operational. A non-functional sprinkler system provides no discount and may actually worsen your claims position.

How does fire safety compliance affect my insurance claim?

Fire and IAR policies contain warranty conditions requiring you to maintain fire protection systems and BOMBA compliance. If a fire occurs while your FC is lapsed, fire alarms are disabled, or sprinklers are not maintained, the insurer may deny or reduce your claim based on warranty breach. Maintaining compliance is essential to protecting your insurance coverage.

What is the cost of fire protection for a typical factory?

For a standard 20,000 sq ft single-storey factory, budget RM150,000 to RM400,000 for complete fire protection system installation. Annual maintenance costs run RM20,000 to RM50,000. Chemical plants and other high-hazard factories will cost significantly more due to specialised systems.

Do I need different fire extinguisher types for different areas of my factory?

Yes. The fire extinguisher type must match the fire classification of the area. Production floors with general combustibles need ABC dry powder. Server rooms and electrical panels need CO2. Commercial kitchens need wet chemical (Class F). Using the wrong type can make a fire worse. Refer to our fire extinguisher requirements guide for detailed matching.

Can BOMBA close down my factory?

Yes. Under the Fire Services Act 1988, JBPM can issue a prohibition notice requiring you to cease operations if your premises pose an immediate fire risk to occupants. This power is exercised in cases of serious non-compliance such as blocked escape routes, non-functional fire systems in high-risk premises, or operating without an FC in a designated premises category.

What documents should I have ready for a BOMBA inspection?

Keep the following accessible: current Fire Certificate, fire safety management plan, fire drill records (last 2 drills), fire system maintenance records, eFEIS certificates for all extinguishers, emergency lighting test records, fire alarm log book, and floor plans showing escape routes and fire equipment locations. Having these organised and readily available demonstrates good compliance practice.

Foundation Insurance Solutions specialises in fire and property insurance for Malaysian factories. We understand how BOMBA compliance connects to your insurance coverage and can help you structure the right protection.

Talk to our factory insurance specialists →

Unlock Exclusive Foundation Content

Subscribe for best practices,
research reports, and more, for your industry

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Want to contact Foundation for your risk or insurance needs?

Let’s Work Together

If you're managing a construction project, industrial facility, or commercial property in Malaysia and need insurance coverage, we can help structure a program that works.

Thank you! Your submission has been received! We'll be in touch with you soon!
Oops! Something went wrong while submitting the form.